Hansin-Hanstar 498- Wrist Strap System Tester
Used to check wrist straps and ground cords, as well as the contact resistance between wrist strap and skin. To operate, simply connect the tester to the ground cord of the wrist strap assembly, and press the finger pad. If the wrist strap and ground cord are working properly (resistance between 500KΩ and 10MΩ), the green "GOOD" lamp will light up and an audible signal will be heard. A lit red "HIGH" lamp, with no audible signal heard, indicates loose contact between wrist band and skin (resistance greater than 10MΩ). A lit red "LOW" lamp, with no audible signal heard, indicates a faulty ground cord resistor (resistance less than 500KΩ). It Comes with 8-ft. grounding wire and 9V battery.
Features:
• Can be used anywhere for quick and easy checking variety of grounding systems.
• Ensures employee safety.
• Eliminates product defects caused by static electricity.
• Battery operated (included)
Specifications
Power Supply 9V Dry Battery
LED Indication Calibration Resistance Buzzer
LOW (Red) R <> 9M ohm OFF
Note: The tolerance in resistance is set to 0 +10% for the
Lower Limit of 800 KiloOhm and -10% to 0 for the upper limit of 9 MegaOhm
-----------------------------------------------------------------------------------------
notes:
1. the Manual
===============
Wrist Strap System Tester EXALT 498
Used to check wrist straps and ground cords, as well as the contact
resistance between wrist strap and skin. To operate, simply connect the
tester to the ground cord of the wrist strap assembly, and press the
finger pad. If the wrist strap and ground cord are working properly
(resistance between 500KΩ and 10MΩ), the green "GOOD" lamp will light up
and an audible signal will be heard. A lit red "HIGH" lamp, with no
audible signal heard, indicates loose contact between wrist band and
skin (resistance greater than 10MΩ). A lit red "LOW" lamp, with no
audible signal heard, indicates a faulty ground cord resistor
(resistance less than 500KΩ). It Comes with 8-ft. grounding wire and 9V
battery.
Features:
• Can be used anywhere for quick and easy checking variety of grounding systems.
• Ensures employee safety.
• Eliminates product defects caused by static electricity.
• Battery operated (included)
Specifications
Power Supply 9V Dry Battery
LED Indication Calibration Resistance Buzzer
LOW (Red) R <> 9M ohm OFF
Note: The tolerance in resistance is set to 0 +10% for the
Lower Limit of 800 KiloOhm and -10% to 0 for the upper limit of 9 MegaOhm