Search Product Code or MPN or SKU here!

Lagunastar Industries Company

软焊 软焊 / はんだ付け はんだ付け
3rd Floor Unit C-22 Banawe de Sta. Rosa Bldg, Balibago, Santa Rosa City, Laguna Philippines 4026
--
Mob. 0933-5996622 SUN ,Mob. 0931-1147369 SUN, Mob. 0976-1479802 Globe , Tel. 049-2542179 --
lagunastar1@yahoo.com, lagunastar1@gmail.com, lagunastar3@yahoo.com ,
--
Skype :lagunastar.industries1 , lagunastar.industries2 , FB page= Soldering Anti-Static

Labels

Apr 17, 2012

Digital Multimeter DT 830D ( Topcraft TDM 600)












Model: TOPCRAFT TDM 600        
A practical tool for electrician use. 
It is easy to operate and the readings indicated directly on the screen.  
It can be use to overhaul all kinds of circuit boards. It is also an ideal teaching instrument for students.
                                                                                                                                                     
Features:  31 digits, 7segment,0.5"high LCD Display   Max display: 1999, Auto polarity display    
 Small and compact design,  Overload protection on all ranges Sampling 2~3 times readings per second.                                  Diode assembly test / Transistor P-N junction test/Transistor hFE test. Low battery voltage indication.  Dimension:125x70x23mm ,        Colour: black         

Max AC Current :10A  ,  Max AC Voltage Range = 1000V 
Max DC Voltage Range = 750V   , Resistance Measurement:200 Ohm-2000K Ohm range
Scale degree & Accuracy:                               
Function
Range
Resolution
Accuracy
DC Voltage
200mV
100uV
±(0.5%+3)
2000mV
1mV
20V
10mV
200V
100mV
1000V
1V
±(0.8%+5)
AC Voltage
200V
100mV
±(1.2%+8)
750V
1V
DC Current
200uA
0.1mA
±(1.0%+5)
2000uA
1uA
20mA
10uA
200mA
100uA
±(1.2%+8)
10A
10mA
±(2.0%+8)
Resistance
200O
0.1O
±(1.0%+8)
2000O
1O
±(1.0%+2)
20KO
10O
200KO
100O
2000KO
1000O









                                                                                                 
 Package included:  1 x Digital Multimeter in box , 2 x Test Leads line (red & black) , 
1 x Manual, 1 x 9V battery.                                                       
 Unit net weight:170g , 
                                                                                                                                                                                                   

Digital Multimeter Excel DT9205A







Digital Multimeter EXCEL DT9205A                                                                                                       Digital multimeter is a great tool for electricians, contractors, and other such professions as well as being a handy tool to have around the house for home repair.
  • Large LCD display with high accuracy
  • Measure AC/ DC voltage, AC/ DC current, resistance, capacitance and diode
  • Stable performance, high reliability ,  Max LCD display: 1999  ,  Operating condition: 0 to 40 deg C 
  • Power Supply:9V battery  ,  Dimension:186mm*86mm*33mm  ,  Weight: 380g
  • Comes with one black test lead and one red test lead
  • LCD display panel angle selection: with the button in the top case, the display panel can be rotated to the best angle
  •  
  • Function
    Range
    Accuracy
    Resolution
    DC Vol.
    200mV
    +-(0.5%+3d)
    0.1mV
    2v
    +-(0.8%+2d)
    1mV
    20v
    10mV
    200v
    0.1V
    1000v
    +-(0.8%+4d)
    0.5V
    AC Vol.
    200mV
    +-(1.2%+5d)
    0.1mV
    2V
    +-(1.0%+5d)
    1mV
    20V
    10mV
    200V
    0.1V
    750V
    +-(1.2%+5d)
    0.375V
    AC Amp.
    2mA
    +-(2.0%+3d)
    0.001mA
    20mA
    0.01mA
    200mA
    +-(2.0%+5d)
    0.1mA
    20A
    +-(3.0%+10d)
    10mA
    DC Amp.
    2mA
    +-(1.0%+5d)
    0.001mA
    20mA
    0.01mA
    200mA
    0.1mA
    20A
    +-(2.0%+10d)
    10mA
    Resistance
    200Ω
    +-(1.0%+10d)
    0.1Ω
    2KΩ
    +-(1.0%+4d)
    20KΩ
    10Ω
    200KΩ
    100Ω
    2MΩ
    1kΩ
    20MΩ
    +-(1.0%+5d)
    10kΩ
    200MΩ
    +-(5.0%+20d)
    100kΩ
    Capacitance
    20nF
    +-(4.0%+5d)
    0.01nF
    200nF
    0.1nF
    2µF
    1nF
    20µF
    10nF
    200µF
    +-(5.0%+10d)
    100nF
    Diode
    Forward current:1mA(Approx); Reverse voltage:2.8V

     

Mar 15, 2012

OCCUPATIONAL SAFETY & HEALTH STANDARDS

OCCUPATIONAL SAFETY & HEALTH STANDARDS
 (DEPARTMENT OF LABOR & EMPLOYMENT, PHILIPPINES, 1996)

1075: Illumination:

1075.01: General Provisions:

All places where persons work or pass or may have to work or pass in emergencies, shall be providedduring time of use with adequate natural lighting or artificial lighting or both, suitable for the operation andthe special type of work performed.

1975.02: Natural Lighting,

(1) Skylights and windows should be located and spaced so that daylight conditions are fairly uniformover the working area.

(2) Where necessary, skylights and windows should be provided with means to avoid glare.

(3) A regular system of cleaning skylights and windows should be established to ensure that they are keptclean at all times.

1075.03: Artificial Lighting:

Quality:

(1) Artificial lighting shall be provided when daylight fails or for area where the daylight illumination isinsufficient.

(2) The general lighting should be of uniform level, widely distributed to avoid harsh shadows or strongcontrast and free from direct or reflected glare.

(3) Where intense local lighting is necessary, a combination of general and supplementary lighting at thepoint of work may be provided.

(4) Supplementary lighting shall be specially designed for the particular visual task and arranged or provided with shading or diffusing devices to prevent glare.


1075.04: Intensity:

(1) Artificial lighting shall be adequate at the place of work for the operation or work performed.

(2) A minimum of 20 lux (2 foot candles) shall be provided for yards, roadways and outside thoroughfares.

(3) A minimum of 50 lux (5-foot candles) shall be provided:

a. where discrimination of detail is not essential, such as handling coarse materials, coal or ashes, roughsorting or grinding of clay products;

b. for passageways, corridors, stairways, warehouses, storerooms for rough and bulky materials.

38
 
(4) A minimum of 100 lux (1 0 foot candles) shall be provided:

a. where slight discrimination of detail is essential such as for the production of semi finished iron andsteel products, rough assembling, milling of grains, opening, picking and carding of cotton, or other primary operation in most of the industrial processes; and

b. for engine and boiler rooms, passenger and freight elevators, crating and boxing departments,receiving and shipping rooms, storerooms, and stockrooms for medium and fine materials, locker rooms,toilets, and washrooms.

(5) A minimum of 200 lux (20 foot candles) shall be provided where moderate discrimination of details isessential, such as for medium assembling, rough bench and machine work, rough inspection of testing of products, sewing light-colored textile or leather products, canning and preserving, meat packing, planingof lumber and veneering.

(6) A minimum of 300 lux (30 foot candles) shall be provided where close discrimination of details isessential such as for medium bench and machine work, medium inspection, fine testing, flour grading,leather finishing and weaving cotton goods or light colored cloth/goods or for office desk work withintermittent reading and writing for filing and mail sorting.

(7) A minimum of 500 to 1,000 lux (50 to 100 foot candles) shall be provided where discrimination of finedetails is involved under conditions of a fair degree of contrasts for long assembling, fine bench andmachine work, fine inspection, fine polishing and beveling of glass, fine wood-working and weaving darkcolored cloth/goods, or for accounting, bookkeeping, drafting, stenographic work, typing or other prolonged close office desk work.

(8) A minimum of I 000 lux (1 00 foot candles) shall be provided where discrimination of extremely finedetail is involved under conditions of poor contrast for long periods of time, such as for extra fineassembling instrument, jewellery, and watch manufacturing, grading and sorting tobacco products, make-up and proof-reading in printing plants, and inspection of sewing dark-colored cloth products.

(9) The provisions of paragraphs 2 to 8 apply to lighting equipment under average operating conditions.Where conditions allow, it may be necessary to provide initially an illumination of at least 25% more. Inlocations where dirt will collect rapidly, the initial level should be at least 50% above the recommendedstandards.

(10) Any windowless room shall be provided with general lighting sufficient in intensity for the mostexacting operations carried therein.

(11) Detailed standards of lighting intensity for different operations of work environment shall be asprovided in Table 8c.

Note: I foot candle = 10.75 lux

For purpose of computation use I foot candle = 10 lux

1075.06: Table of Illumination Levels:

Table 8c



1075.06: Emergency Lighting:

(1) Where large numbers of persons are employed in buildings more than one story in height, emergencylighting system shall be provided in all important stairways, exits, workplaces and passages.

(2) Emergency systems shall be capable of producing and maintaining for at least one (1)

hour, aminimum intensity of 5 lux (0.5 ft. candle) and shall have an energy source

independent of the generallighting system installation.

39
 
(3) Provisions shall be made for the automatic lighting of the emergency system immediately upon failureof the general lighting system.

Source = http://www.scribd.com/doc/12040887/DOLE-Occupational-Safety-and-Health-Standards

Mar 9, 2012

Surface Resistivity Checker BOSCHSTAT BSC-SRM



BSC-SRM Surface Resistance Meter

BSC-SRM is an ultra wide-range, battery operated, portable instrument for measuring Surface Resistivity of virtually any flat surface conforming to ASTM D-257 standard by using recommended parallel bar sensing probe. In the circuit industry, products such as packaging materials, ESD shielding bags, work bench surfaces, static dissipative table and floor mats, conveyor belts, etc, have resistance values which need to conform to stringent specifications, Moreover, these values are expected to fall with in specified limits. The Surface Resistivity Meter can play a vital role in monitoring and checking the resistivity characteristic of the above items.
Specification:
Operating Temperature
0-50
Relative Humidity
0%-80% RH
Test Voltage
9 volts
Size
137(L)×76(W)×30(D)mm
Weight
120g
Accuracy
± 1/2 decade
Repeatability
± 5%
Measurement Range
103-1012 ohms per square
Resolution
One decade
Indication
Visual by LED’S
Test Actuation
ON / OFF Switch
Power Supply
9 volt DC Battery
Calibration
Recommended every 12 months
Warranty
12 months
Accessories include
1m Grounding Cord & Carrying Leather Bag

It also has unique additional feature of surface-to-ground measurement capability wherein the resistivity differential between any surface and any chosen ground can be determined.

The surface resistivity is conveniently indicated by a row of LED’s covering a total of 10 decades from 103-1012 ohms per square.

Instruction to use:
Place the meter on the material to be tested and push the RED button in the middle of the unit. The unit measures the resistance between two electrodes on the back of the meter to determine surface resistivity, The LED that is lit, will indicate the surface resistivity in ohms per square.
Readings in Conductive Band
103= 1K Ohm
104= 10K Ohms
105= 100K Ohms

Readings in Insulating Band
1012= 1,000,000 Meg Ohms or greater

Readings in Static Dissipative Band
106= 1 Meg Ohms
107= 10 Meg Ohms
108= 100 Meg Ohms
109= 1,000 Meg Ohms
1010= 10,000 Meg Ohms
1011= 100,000 Meg Ohms

Resistance to ground measurement
Plug the stereo plug of the ground lead into the jack marked GROUND on the side of the meter. Connect the alligator clip to a suitable ground point for the material to the tested. For table mats, this will be generally be the snap for the mats ground cord. Place the meter in the desired location and push the RED test button. The unit will measure the resistance from the electrode on the right to the ground point. RTG values are measured in Ohms.


Pls see Older Post or Labels

Pls see Older Post or Labels