HANSTAR 5800B
Overhead IONIZING AIR BLOWER- 2 fan
1. The overhead ionizing blower produces an air flow that is rich in positive and negative ions. Directing the air flow on an object that has a static electricity charge will neutralize the charge.
2. The overhead ionizing blower has 2 small fans to produce air flow. The volume of air flow is controlled by a variable speed control which provides a wide range of air flow setting. The high voltage AC is applied to a circular arrangement of tungsten steel ion emitter points which results in an intense alternating electric field at the tips of the emitter points. It is this electric field that creates alternating polarity ions in the air flow. To assure that the unit is working properly, the high voltage AC is monitored by an ionization indicator lamp.
3. The overhead ionizing blower features a patented balancing circuit. Also features a patented built-in emitter point clear. Using the point clear takes only seconds. Cleaning the emitter points on a weekly basis prevents the build-up of airborne debris all electrical ionizers are prone to. This keeps your blower working in top form for the life of the unit.
4. Widely used in the field of Data Storage Manufacturing, Electronics Assembly, Semiconductor Manufacturing, Pharmaceutical Plant, & in Explosives -Product Productions
Specification:
Operating Voltage: 110V/60HZ OR 220V/50HZ
Current Consumption ≤ 0.9A
Air Volume: 90~220 CFM
Air Coverage: 40cm×90cm
Working Temperature: 0 to 50deg C
Sound: 50 to 60 dB
Weight: about 7.5 Kg
Size: 600mm (L)×90mm(W)×170mm(H)
Ion Balance: 0V±10V
Decay test results:
Testing conditions | ||||
Operating voltage = 110V/220V | Testing voltage= 1KV to 100V | Temperature: | ||
Distance | | | | |
Left | 1.3s | 1.9s | 3.0s | 4.2s |
Centre | 1.3s | 1.7s | 3.2s | 3.5s |
Right | 1.4s | 2.3s | 3.4s | 4.5s |
Remarks:
1. Distance measured in mm, decay time measured in seconds.
2. Test data from ME
3. Test figures are subject to the variation in the atmospheric conditions.