Mar 25, 2025
Mar 24, 2025
HAKKO FX-888DX JAPAN Digital Soldering Station
SOLDERING STATION HAKKO FX-888DX
SKU= HAKKO-FX-888DX
FX888DX-81BY HAKKO
Easy to operate. Settings can be easily made by turning the rotary encoder to "select" and pressing the rotary encoder to "confirm".
Optional 95W soldering iron can be connected.
The main body is available in 3 colors. It can be used in various ways.
Specification
Power supply (V): AC100
Power consumption (W): 100
Set temperature (℃): 50-480
Heater capacity (W): 65
Color: Blue/yellow
Power cord length (m): 1.2
Ripple temperature (℃): ±1 (at no load)
【Specification2】
Tip-to-earth resistance: 2Ω or less
Leakage voltage: 2mV or less
Heater: Ceramic heater
【Material/Finish】
-
【Set contents/accessories】
Station main body (FX-888DX)
Soldering iron part (FX8801-01)
Soldering iron stand (FH800-05SV)
Power cord
Soldering Tester GOOT TM-200 from japan
Soldering Tester GOOT TM-200
TAIYO ELECTRIC IND.CO.,LTD.Japan1.000KG●With a comparator function that automatically performs pass/fail judgment based on the measured value.●Long life sensor enabling 200 times or more measurement.●For measuring iron tip temperature for soldering irons.●W x D x H (mm):185 x 160 x 58●Power supply: 100-240V AC50/60Hz●Measuring temperature range: 0 to 500●C(sensor TM-100S)●Temperature accuracy: 0 to 500● ?}3●(excluding sensor errors)●Set contents: Sensor(3pcs)/Test lead/Fuse
●With a comparator function that automatically performs pass/fail judgment based on the measured value.●Long life sensor enabling 200 times or more measurement.●For measuring iron tip temperature for soldering irons.●W x D x H (mm):185 x 160 x 58●Power supply: 100-240V AC50/60Hz●Measuring temperature range: 0 to 500●C(sensor TM-100S)●Temperature accuracy: 0 to 500● ?}3●(excluding sensor errors)●Set contents: Sensor(3pcs)/Test lead/Fuse
Soldering Tip Thermometer HAKKO FG100B from japan
Measurement results can be sent to compatible soldering irons via IR communication.
Automates the process of reading the tip temperature and calculating the average value.
The number of temperature measurements is displayed, so you can know when to replace the sensor.
SOLDERING Thermometer H-769 HOZAN from japan
Result of measurement can be saved in an SD card.With a pass/fail judgment function displaying OK/NG based on the result of measurement.With soldering iron identification function for controlling the soldering iron using an IC tag.For measuring iron tip temperature.W x D x H (mm):110 x 155 x 66Measuring range: 0 to 500CResolution: 1Maximum display: 999 countsPower Supply: AA battery x 4
SOLDERING THERMOMETER GOOT TM-100 from JAPAN
Iron tip temperature can be instantly measured with high accuracy. Best iron tip thermometer in industry with excellent stability and responsiveness.Long life economical sensor.Count alarm display allowing you to have a general idea of sensor life.For measuring iron tip temperature for soldering irons.W x D x H (mm):83 x 38 x 140Measuring range: 0 to 700CPower supply: AA battery x 4
Mar 17, 2025
Liquid Turbine Flow Meter SLW series
Liquid Turbine Flow Meter Overview
SLW series Turbine Flow Meter has simple structure, light weight, high-accuracy, perfect repeatability, sensitivity, easy maintenance and use. It is a kind of volumetric flow meter and low cost flow meter which are widely used to measure liquid which has no chemical corrosive reaction with stainless stee1Cr18Ni8Ti, 2Cr13, corundum Al2O3and cemented carbide. This kind of measured liquid has no impurities such as fiber and particles. The movement viscosity is lower than 5×10-6m2/s at working temperature. If the viscosity is higher than 5×10-6m2/s, turbine flow meter manufacturer will calibrate in the liquid before use, so it is good to use as oil flow sensor ,such as digital diesel flow meter. It can finish batch control, alarm and etc,if matched with digital controllers. It is also the ideal turbine meter for flow measuring and energy saving (such as used as LPG flow meter or digital fuel flow meter,palm oil flow meter)
Features of Liquid Turbine Flow Meter
• High accuracy; Normal type can reach ±1%R, ±0.5%R.High accuracy type can reach to ±0.25%R.
• Excellent repeatability, repeatability in a short time can reach to 0.05%~0.2%.Due to the excellent repeatability; customers buy flow meter and use it for trade purpose.
• Turbine flow transmitter Output pulse frequency signal, suitable for total flow measuring (work as totalizing flow meter) and connecting upper computer through Modbus RS485, it can also be analog flow meter
• Turbine flow sensor no zero drift and strong ability in anti-noise.
• High frequency signal (10Hz~1.5 KHz), strong signal resolution.
• SLW series Turbine Flow Meter with wide turn down ratio, max 1:20,can be used as pure water flow meter, digital portable water flow meter, cheap RO water flow meter
• Compact and light structure, convenience in installation and maintenance, cheap China flow meter.
• Suitable to measure in high pressure .No need to open aperture on the meter, so it is easy to make high pressure flow meter.
• It is custom turbine flow meter. it can be thread connection turbine flow or sanitary turbine flow meter (tri-clover liquid flow meter), and it can even be made as low flow turbine flow meter with flow meter sensor size only DN4.
• SLW series Turbine Flow Meter can max bear 150℃, so it can be used as hot water meter or measure other high temperature medium.
Technical Specification of Liquid Turbine Flow Meter
Manufacture Standard | Turbine flow meter (JB/T9246-1999) | |
Turbine Flow Medium | Clean, low viscosity(≤5×10-6m2/ s) ,non-corrosive liquid | |
Flange Standard | Standard GB/T9113-2000,option ANSI,JIS,DIN | |
Thread Standard | StandardBSPP(male),optionBSPP (female), NPT.,etc. | |
Turbine Flow meter Accuracy | 1.0%,0.5% | |
Turn Down Ratio | 1:10-1:20 | |
Calibration | Methods | Master meter calibration |
Static weigh mass flow calibration | ||
Environment | Environment temperature: 20℃ | |
Relative Humidity :65% | ||
Working Condition | Medium temperature | T1: -20 ~80℃ |
T2: -20 ~120℃ | ||
T3: -20 ~150℃ | ||
Environmenttemperature | -20 ~60℃ | |
Relative Humidity | 5%-90% | |
Atmospheric pressure | 86Kpa-106Kpa | |
Enclosure Protection | SLW-N:IP60; othersIP65 | |
Transmission Distance | No more than 1000 m | |
Turbine Flow sensorMaterial | Housing: Standard-304 Stainless Steel ; Optional - 316 Stainless Steel Bearings and Shaft: Tungsten Carbide ; Rotor:2Cr13 Stainless Steel Retaining Rings:304 Stainless Steel | |
Turbine meterConsumption | < 1W | |
Communication | Modbus RTU/Hart Protocol turbine flow meter |
Turbine Flow meter Flow Range & Process Connection & Pressure Rating
Size (mm) | Standard Flow (m3/h) | Extended Flow (m3/h) | Connection | Standard Pressure | Special Pressure |
DN4 | 0.04-0.25 | 0.04-0.24 | Thread | 6.3 Mpa | ≤16Mpa |
Wafer | 1.6Mpa | ≤42Mpa | |||
DN6 | 0.1-0.6 | 0.06-0.6 | Thread | 6.3 Mpa | ≤16Mpa |
Wafer | 1.6Mpa | ≤42Mpa | |||
DN10 | 0.2-1.2 | 0.15-1.5 | Thread | 6.3 Mpa | ≤16Mpa |
Wafer | 1.6Mpa | ≤42Mpa | |||
DN15 | 0.6-6 | 0.4-8 | Thread | 6.3 Mpa | ≤16Mpa |
Wafer | 1.6Mpa | ≤42Mpa | |||
Flange | 4.0Mpa | ≤10Mpa | |||
DN20 | 0.8-8 | 0.45-9 | Thread | 6.3 Mpa | ≤16Mpa |
Wafer | 1.6Mpa | ≤42Mpa | |||
Flange | 4.0Mpa | ≤10Mpa | |||
DN25 | 1-10 | 0.5-10 | Thread | 6.3 Mpa | ≤16Mpa |
Wafer | 1.6Mpa | ≤42Mpa | |||
Flange | 4.0Mpa | ≤10Mpa | |||
DN32 | 1.5-15 | 0.8-15 | Thread | 6.3 Mpa | ≤16Mpa |
Wafer | 1.6Mpa | ≤42Mpa | |||
Flange | 4.0Mpa | ≤10Mpa | |||
DN40 | 2-20 | 1-20 | Thread | 6.3 Mpa | ≤16Mpa |
Wafer | 1.6Mpa | ≤42Mpa | |||
Flange | 4.0Mpa | ≤10Mpa | |||
DN50 | 4-40 | 2-40 | Thread | 1.6Mpa | ≤16Mpa |
Wafer | 1.6Mpa | ≤25Mpa | |||
Flange | 4.0Mpa | ≤10Mpa | |||
DN65 | 7-70 | 4-70 | Thread | 1.6Mpa | ≤16Mpa |
Wafer | 1.6Mpa | ≤25Mpa | |||
Flange | 1.6Mpa | ≤6.3Mpa | |||
DN80 | 10-100 | 5-100 | Thread | 1.6Mpa | ≤16Mpa |
Wafer | 1.6Mpa | ≤25Mpa | |||
Flange | 1.6Mpa | ≤6.3Mpa | |||
DN100 | 20-200 | 10-200 | Wafer | 1.6Mpa | ≤16Mpa |
Flange | 1.6Mpa | ≤6.3Mpa | |||
DN125 | 25-250 | 13-250 | Wafer | 1.6Mpa | ≤16Mpa |
Flange | 1.6Mpa | ≤2.5Mpa | |||
DN150 | 30-300 | 15-300 | Wafer | 1.6Mpa | ≤16Mpa |
Flange | 1.6Mpa | ≤2.5Mpa | |||
DN200 | 80-800 | 40-800 | Wafer | 1.6Mpa | ≤10Mpa |
Flange | 1.6Mpa | ≤2.5Mpa |